9
When the circuit is connected as shown in figure 1.4, the switches of the emulator are set as SW2
= 1 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the SuperH
TM
Family E10A-USB Emulator User’s Manual.
1
TCK
TMS
RESET
TDI
TDO
TRST
ASEBRK
/ BRKACK
GND
GND
GND
GND
(GND)
2
3
4
5
6
7
8
9
11
10
12
13
14
TCK
TMS
TDO
TDI
TRST
ASEBRK/BRKACK
VccQ
VccQ
N.C.
VccQ
VccQ
VccQ
UVCC
VccQ
H-UDI port connector
(14-pin type)
SH7343
All pulled-up at 4.7 kΩ or more
1 kΩ
User system
VccQ = 2.85-V I/O power supply
RESETP
MPMD
RESETA
RESETMFI
Reset signal
Power-on reset signal
MFI reset signal
*2
*2
*1
*3
Level-
shift
circuit
Figure 1.4 Recommended Circuit for Connection between the H-UDI Port Connector and
MPU when the Emulator is in Use (14-Pin Type)
Notes: 1. Do not use /RESETP in the emulator after the user system has been activated.
When reset signals are used for debugging, use /RESETA or /RESETMFI.
2. Fix /RESETA and /RESETMFI as high levels when they are not used.
3. When VccQ_MFI is used at 1.8 V, the level-shift circuit in figure 1.4 is required to
adjust the signal levels.