( 29 / 52 )
Figure 3.10 Removing pod probe M301xxT-PRB
(1) Unscrew the two screws of the M301xxT-PRB.
(2) Remove the M301xxT-PRB from the FLX64-PRB. In
this time, lift off the M301xxT-PRB horizontally.
Otherwise, the connector may cause a break.
CAUTION
When Connecting the Pod Probe:
• Be sure to turn off the power before making connections. Otherwise, the internal
circuits may be damaged.
• The small connectors of the M301xxT-PRB (J1 and J2) and FLX64-PRB (J3 and J4)
are guaranteed for only 50 insertion/removal iterations.
3.5 Connecting the Pod Probe
The emulation pod for the M16C/10 Series MCUs consists of the two products, the M30100T3-RPD-
E emulation pod main unit and the M301xxT-PRB pod probe ("x" denotes number). Figures 3.9 and
3.10 show how to connect the M301xxT-PRB and how to remove it, respectively.
Figure 3.9 Connecting pod probe M301xxT-PRB
(1) Connect connectors J1 and J2 of the M301xxT-PRB to
connectors J3 and J4 of the FLX64-PRB.
(2) Fix the FLX64-PRB by the two screws.