21
Video fuzzy
Cable too long or wrong type. Use coax cable for high resolution.
Mouse does not move
The Vista is turned off after or not connected when CPU was booted
or the application using the mouse was run. Exit and re-enter
application or operating system using mouse or issue reset command.
PS/2 mouse was not connected when the Vista was powered up or
the mouse was disconnected and reconnected. Issue the reset
command.
Mouse translation set incorrectly.
Video not synchronized or wrong color
The cable may be loose, reseat cable.
Wrong CPU cable used. If you have a 9515, 9517, 9518, XGA mono
or similar monitor you must use special cables or adapters.
Cable is defective; try using cable from another CPU if problem goes
away cable is defective.
Port on the Vista is defective; try using another port on the Vista. If
problem goes away port is defective.
Cannot remember the configuration or access password.
Call Rose Electronics Technical Support for instructions.