3 Technical Specifications
3.1 Type Test Specifications
IEC 61000-6-2 EMC: Generic Standards - Immunity for industrial environments
Test Description Levels
Enclosure Contact +/- 4kV
IEC 61000-4-2 ESD
Enclosure Air +/- 8kV
IEC 61000-4-3 Radiated RFI Enclosure ports 10 V/m, 80 to 1000Mhz
Signal ports +/- 1kV @ 5kHz
IEC 61000-4-4
Burst (Fast
Transient)
DC Power ports +/- 1kV @ 5kHz
Signal ports +/- 1kV line-to-earth/line
IEC 61000-4-5 Surge
DC Power ports
+/- 0.5kV line-to-line
+/- 1kV line-to-earth
Signal ports
DC Power ports
IEC 61000-4-6
Induced
(Conducted) RFI
Earth ground ports
10V @ 0, 5-80 MHz
IEC 61000-4-8 Magnetic Field Enclosure ports 30 A/m @ 50, 60 Hz
IEC 61000-4-11 Voltage Dips DC Power ports 30% reduction for 0.5 period
Signal ports
IEC 61000-4-12 Damped Oscillatory
DC Power ports
1kV common mode
0.5kV differential mode
Signal ports
IEC 61000-4-16
Mains Frequency
Voltage
DC Power ports
10V continuous
100V for 1s
IEC 61000-4-17
Ripple on D.C.
Power Supply
DC Power ports 10%
Table 7: Electromagnetic Compatibility tests
IEC Environmental Type Tests
Test Description Test Levels
IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Hours
IEC 60068-2-2 Dry Heat Test Bd +85°C, 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing), 55°C , 6
cycles
IEC 60255-21-1 Vibration Tests Fc 1g @ (10 - 500) Hz
IEC 60255-21-2 Shock Tests Ea 30g @ 11mS
Table 8: Environmental Type Tests