2.4 Dielectric Strength Testing
For dielectric strength testing in the field, users must remove the metal jumper located on terminal
2, 4, and 6 of the power supply terminal block. This metal jumper connects transient suppression
circuitry to chassis ground, and must be removed in order to avoid damage to protection circuits.
Figure 4 shows the proper dielectric strength test connections and should be followed to avoid
damage to the device.
Chassis
Ground
Surge
Ground
Figure 4: Dielectric Strength (HIPOT) Testing