Check the indicators for projector’s condition.
• • •
green
• • •
red
• • •
off
• • •
blinking green
* When the projection lamp reaches its end of life, the LAMP REPLACE indicator lights yellow. When this indicator becomes yellow,
replace the projection lamp with a new one promptly. Reset the Lamp replacement counter after replacing the lamp. The time
when the LAMP REPLACE indicator should light is depending on the lamp mode. See pages 49 – 50.
Indicators and Projector Condition
• • •
blinking red
• • •
blinking orange
• • •
blinking yellow
Appendix
Indicators
Projector Condition
POWER
red/green/
orange
WARNING
red
LAMP
REPLACE
yellow
The Main On/Off switch is off or the AC power cord is unplugged.
The projection lamp is being cooled down. The projector cannot be turned
on until cooling is completed.
The projector is ready to be turned on with the POWER ON/STAND-BY
button.
The projector is operating normally.
The projector is in the Power management mode.
The temperature inside the projector is abnormally high. The projector
cannot be turned on. When the projector is cooled down enough and the
temperature returns to normal, the POWER indicator emits red light and the
projector can be turned on. (The WARNING indicator keeps blinking.) Check
and clean the air filter.
The projector has been cooled down enough and the inside temperature
returns to normal. When turning on the projector, the WARNING indicator
stops blinking. Check and clean the air filter.
The projector detects an abnormal condition and cannot be turned on.
Unplug the AC power cord and plug it again to turn on the projector. If
the projector is turned off again, unplug the AC power cord and contact
the dealer or service center for servicing and checkup. Do not leave the
projector on. It may cause an electric shock or a fire hazard.
The lamp does not turn on because malfunction occurs or the lamp reaches
its end of life.
The automatic slide shutter is not working properly.
✽
✽
✽
✽
✽
✽
✽
✽