Programming Manual 4. Bar Code Specifications
SATO RISC Printers 151
Postnet
Command Structure:
<ESC>BP (data)
data: 5 digits ZIP
6 digits for Postnet 37
9 digits for ZIP+4
11 digits for Dlelivery Point Bar Code
Character Set:
1-9 (numeric only)
Input:
<ESC>H0100<ESC>V0120<ESC>BP94089
<ESC>H0100<ESC>V0160<ESC>BP123456
<ESC>H0100<ESC>V0200<ESC>BP123456789
<ESC>H0100<ESC>V0240<ESC>BP12345678901
Output:
Note:
1. Frame bits and check digits added automatically by printer.
2. Bar code width and height are fixed and cannot be changed.
3. If the number of digits sent to the printer as data does not match
one ofthe formats specified above (i.e. 5, 6, 9 or 11), the command
is ignored and nothing will be printed.
4. If a “–” is included in the data stream (i.e. 84093-1565), it is
ignored.