CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 47
Y Information exceptions control page
(1Ch)
Y Background Scan mode subpage
(01h)
1Bh Y Start unit/stop unit Y Y Executable Executable
1Ch Y Receive diagnostic results Y N Executable Executable
Y Supported diagnostics pages
Y Translate page
Y Enclosure services page
1Dh Y Send diagnostics page Y N Executable Executable
Y Supported diagnostics pages
Y Translate page
25h Y Read capacity Y N Executable Executable
28h Y Read extended
Y Disable page out
Y Force unit access
N Relative address
2Ah Y Write extended
Y Disable page out
Y Force unit access
N Relative address
2Bh Y Seek extended
2Eh Y Write and verify N Y Executable Check Condition
Y Disable page out
Y Byte check
N Relative address
2Fh Y Verify (10) (BYTCHK = 0) N Y Executable Executable
Y Verify (10) (BYTCHK = 1) N Y Executable Check Condition
Y Disable page out
Y Byte check
N Relative address
30h N Search data high
31h N Search data equal
32h N Search data low
33h N Set limits
34h N Prefetch N Y Executable Check Condition
35h Y Synchronize cache N Y Executable Executable
36h N Lock-unlock-cache
37h Y Read defect data Y N Executable Executable
39h N Compare
3Ah N Copy and verify
3Bh Y Write buffer N Y Check Condition Check Condition
(all modes except modes 4h - 7h, 0Eh, and 0Fh)
Y N Executable Executable
(modes 4h - 7h, 0Eh, and 0Fh)
Table 16 Supported commands (continued)
Command
code
Supported
(Y/N) [4] Command name
Executable state of standard SCSI commands in the presence of
LBA banding (applies to SED models only)
Affects entire
Drive (Y/N)
User Data
Accessed
(Y/N)
Affected LBA
Unlocked
ReadLock=Write
Lock=False
Affected LBA
Locked
ReadLock=Write
Lock=True