ID NUMBER ID NO. SETTING IDST W 0 - 255 It sets the monitor's ID number.
R 0 - 255 It returns the monitor's ID number.
IDSL W 1 - 255
Sets a monitor ID number. This ID number is only effective for the command
immediately after this command.
0 Clears the ID number if one has been designated.
IDLK W 1 - 255
Sets a monitor ID number. This ID number is effective for the next and all
subsequent commands after this command.
0 Clears the ID number if one has been designated.
ID CHECK IDCK W Displays selected ID number and the monitor's own ID number on the screen.
CONTROL LOCK MENU DISPLAY LMNU WR Normal (Menu Display is available)
1 1 Menu Display is not available.
REMOTE CONTROL LREM WR Normal (Operational)
1 1 Disabled
CONTROL BUTTONS LBTN WR Normal (Operational)
1 1 Disabled
POWER LPOW WR Normal (Operational)
1 1 Disabled
RS232C LCOM WR Normal (Operational)
1 1 Disabled
PIN SET PIN PSET W 4 digits Sets PIN (Activates lock function)
PSE+ W 4 digits Sets PIN: for repeater control
INPUT PIN PINP W 4 digits Input of set PIN (Temporary unlock)
PIN+ W 4 digits Input of set PIN: for repeater control
CLEAR PIN PCLR W 4 digits Initializes PIN
PCL+ W 4 digits Initializes PIN: for repeater control
POWER-ON METHOD, ETC. MAX VOLUME MVOL WR 1 - 60 1 - 60 Maximum volume limit. Only displays volume in numbers when set to other than 60.
FIX VOLUME FVOL WR 0 0 Off
1 1 Fixes volume at a constant value
OSD SETTING ODSP WR 0 0 Normal
1 1 No OSD is displayed.
DISPLAY BOOT FINP WR 0 0 Normal
OPTION 1 1 Starts with INPUT1 + [AV] input selection
2 2 Starts with INPUT1 + [Y/C] input selection
4 4 Starts with INPUT2. Returns ERR if INPUT2 selection is "Output"
5 5 Starts with INPUT3.
6 6 Starts with PC + [Analog] input selection
7 7 Starts with PC + [Digital] input selection
11 11 Starts with INPUT1 + [AV] input selection, and remains fixed
12 12 Starts with INPUT1 + [Y/C] input selection, and remains fixed
14 14
Starts with INPUT2, and remains fixed. Returns ERR if INPUT2 selection is "Output".
15 15 Starts with INPUT3, and remains fixed
16 16 Starts with PC + [Analog] input selection, and remains fixed
17 17 Starts with PC + [Digital] input selection, and remains fixed
SOUND INPUT SELECT SNDS WR 0 0 Normal
1 1 Uses INPUT1 audio as fixed source
2 2 Uses INPUT2 audio as fixed source
COVR WR 0 0 Detached
1 1 Attached
PANEL PROTECTION COVER
ID NO. SETTING
(ONCE)
ID NO. SETTING
(SUBSEQUENT)
Maximum volume limit. Only displays volume in numbers when set to other than 60.