Sigma 880 Projector User Manual


 
2.7
OPERATING INSTRUCTIONS
STEP 3
8
9
Connecting the remote control cable
Close the jaws of the control cable connector
over the joined connectors.
Slide the remote control connector assembly collar
over the connector jaws.
NOTE The control cable connector, when properly
installed with the selector ring in the CONNECT
position, displaces anti-rotation lugs which allows
the selector ring to be rotated to the LOCK position
and when required, through to the OPERATE position.
Push and hold the remote control connector
assembly collar flush against the exposure device’s
locking mechanism and rotate the selector ring
from CONNECT to LOCK. The selector ring can
be secured in this position by engaging the
plunger lock.
Do not rotate past LOCK.
The remote control cable connector is now secured
into the exposure device's locking mechanism.
Keep the exposure device in the LOCK position
until ready to start the exposure.
Checks before exposure of the source
Verify that the source guide tubes are attached to the outlet port.
Verify that the remote control connector assembly is correctly connected to the exposure
device’s locking mechanism.
Ensure that no personnel are inside the Restricted Area or exposure room.
Ensure that the proper signs are posted and required warnings are in operation.
NOTE
If the remote control is fitted with an additional lock, release this lock and apply a
forward motion to the control crank handle, as if exposing the source, until a resistance
is felt. Release the control crank handle and proceed with the next step.
CAUTION
Do not apply excessive force to the control crank handle in the expose direction as this could
cause the source assembly to move forward out of the stored position when the lock slide
is released. Do not retract the control cable and apply the control crank brake. Leave the
control crank and the control cable in a neutral tension position.