Page 49 of 66
intelligent wireless platform
airClient™ Nexus User Guide
The following page summarizes the page contents of the System Configuration page.
Table 7-1 System Configuration Page Items
7.1.1. SNMP Security
The user can edit the SNMP Community String and SNMP Access filters. The SNMP community needs to
match with the SNMP monitoring software used. The SNMP Access Filters allows you to determine which
host(s) is authorized to monitor the device using SNMP. It is recommended that you set this for security
reason and to prevent an attack. To change the SNMP security settings, click on the SNMP security link
in the System Configuration page. Figure 7-2 shows the SNMP Security Configuration page.
Page Item Descriptions.
System Name
Displays name of airClient unit
Allows user to change airClient unit name
System Description
Displays description of airClient unit
Allows user to change airClient unit description
SNMP Security
Access the SNMP security settings
Reset
Reset device
Reset To Factory
Defaults
Reset device to factory defaults
Delayed Reset
Schedule a reset
NTP Server
NTP server setup, as well as NTP time if server is setup
Software Version
Display the installed firmware version
Radio Firmware
Version
Display the installed radio firmware version
Edit Configuration
Provide links to edit IP, radio, configurations
Ethernet MTU Size
Set the Ethernet MTU Size
Syslog server IP
Address
Display the current message Syslog server IP Address.
User can change the IP address.
SNMP Trap IP
Display the current SNMP trap IP address.
User can change the IP address.
Log Level
Display the current Log Level
Watch Guard
Suspends/Enables the radio defenders.
If the Watch Guard is Suspended the defenders will stop for 2 hours and start
again thereafter.
If the Watch Guard is enabled the radio defender’s will start immediately.
Note: The Radio Defenders will monitor the Wireless Association Status
(automatically) and traffic and take corrective action if needed.
LED Control
Display the current led on status.
User can change the LED status to on/off
Current
Operational mode
Display the current operational mode.
User can change the current operational mode.