Sony NSP-100 Network Router User Manual


 
NSP 100
Precautions / Alarm Indications
26
Others
Precautions
On operation and storage locations
Avoid operation or storage in any of the following
places.
Location subject to extremes of temperature
(operating temperature range 5
°
C to 40
°
C (41
°
F to
104
°
F))
Location subject to direct sunlight for long periods, or
close to heating appliances (Note that the interior of a
car left in summer with the windows closed can
exceed 50
°
C (122
°
F).)
Damp or dusty places
Location subject to severe vibrations
Location near equipment generating strong
electromagnetic emissions
Location near transmitting stations generating strong
radio waves
Operate the unit in a horizontal position
This unit is designed to be operated in a horizontal
position. Do not operate it on its side, or tilted through
an excessive angle (exceeding 20
°
).
Dropping the unit, or otherwise imparting a violent
shock to it, is likely to cause it to malfunction.
Avoid violent impacts
Dropping the unit, or otherwise imparting a violent
shock to it, is likely to cause it to malfunction.
Do not obstruct ventilation openings
To prevent the unit from overheating, do not obstruct
ventilation openings, by for example wrapping the unit
in a cloth while it is in operation.
On cleaning
If the casing or panel is dirty, wipe it gently with a soft
dry cloth. In the event of extreme dirt, use a cloth
steeped in a neutral detergent to remove the dirt, then
wipe with a dry cloth. Applying alcohol, thinners,
insecticides, or other volatile solvents may result in
deforming the casing or damaging the finish.
On repacking and shipping
Save the original shipping carton and packing material;
they will come in handy if you ever have to ship your
unit.
For maximum protection, repack your unit as it was
originally packed at the factory, and take care not to
impart violent shocks in transit.
Alarm Indications
The temperature range for guaranteed operation of this
unit is from 5
°
C to 40
°
C (41
°
F to 104
°
F). If operated
outside this temperature range, the life of the unit may
be reduced, or the internal hard disk drive may fail.
The following alarm icons appear at the lower left of the
menu screen to indicate an abnormal temperature within
the unit or other problems.
Indication Meaning and action to take
High temperature warning
The internal temperature has risen into the range
65
°
C
to 79
°
C (149
°
F to 174
°
F)
.
g
Check that the ventilation openings in the
upper and lower surfaces are not obstructed.
Check the ambient temperature.
High temperature fault
The internal temperature has risen to 80
°
C
(176
°
F
) or above.
g
Check that the ventilation openings in the
upper and lower surfaces are not obstructed.
Check the ambient temperature.
Low temperature warning
The internal temperature has fallen into the range
1°
C
to 5
°
C (34
°
F to 41
°
F)
.
g Check the ambient temperature.
Low temperature fault
The internal temperature has fallen to 0°
C
(32
°
F)
or below.
g Check the ambient temperature.
Hard disk drive warning
The internal hard disk is failing. Replace it as
soon as possible.
g Consult your supplier or Sony service
representative.
Hard disk drive fault
The internal hard disk has failed, and must be
replaced.
g Consult your supplier or Sony service
representative.
Fan stopped
The internal fan has stopped.
If this is not corrected, it may lead to excessive
internal temperatures.
g Consult your supplier or Sony service
representative.
Remote controller not accepted
The unit cannot be operated from a remote
controller.
(For example when under the control of the
BZNP-100 Software)