Sony SNT-V304 Webcam User Manual


 
43
Alarm Inputs
Four photocoupler inputs are provided for alarm
inputs. Alarm signals can be connected to any of the
inputs as follows.
To use the electrically isolated inputs, the connected
device must have 5 to 20-V DC output, connected as
follows.
If an alarm device has mechanically switched or open-
collector outputs that do not need to be electrically
isolated, connect as follows.
Note
Insert a protective diode when connecting a conductive
load, such as a relay, to alarm out pins 15 and 16.
Inside server←→Outside server
Approx. 4.7 k
Alarm Device
5 to 20V DC Output
Max. 24V AC/DC
@100 mA
Pins 3, 5, 11 and 13
+
Pins 4, 6, 12 and 14
Pin 15
Pin 16
Inside server←→Outside server
Approx. 4.7 k
Pins 3, 5, 11 and 13
Pins 4, 6, 12 and 14
Pin 9
Pin 10
Mechanically switched
output device
Mechanically
switched output
device