Miscellaneous
Specifications
60
When IMMED. CAP. is set to OFF:
The above example shows that the images at the seventh
and eighth positions are captured. However, images at
other positions could be captured depending on the
printer mode and printer settings.
Note
When AUTO LIVE of the FUNCTION SETUP menu is
set to OFF, the memory image is displayed on the screen
after the image is captured in memory. In such a case,
whenever you capture an image, press the SOURCE/
MEMORY button so that the source image appears on
the video monitor. Displaying the memory image does
not allow you to capture the image with the correct
timing.
When IMMED. CAP. is set to ON:
Note
This mode is effective only when the source image is
displayed on the monitor screen. If the memory image is
displayed, the image will not be captured even if the
pulse is sent to the printer. Be sure to display the source
image when sending the pulse.
Design and specifications are subject to change without
notice.
Notation Parameter MIN TYP MAX Unit Remarks
tRPE Time within
which a remote
control pulse
should be cleared
to zero.
3 - 12 msec -
tRPW Length of a
remote control
pulse
100 - - msec -
VRP Amplitude of a
remote control
pulse
- - 5 V This value is
based on the
TTL standard.
Remote control
pulse signal
Captured image
Notation Parameter MIN TYP MAX Unit Remarks
tRPE Time within
which a remote
control pulse
should be cleared
to zero.
3 - 10 msec -
tRPW Length of a
remote control
pulse
100 - - msec -
VRP Amplitude of a
remote control
pulse
- - 5 V This value is
based on the
TTL standard.
Captured image
Remote control
pulse signal