SpectraLink 1728 Computer Hardware User Manual


 
14 REFERENCE & INSTALLATION MANUAL
3.2.2 FEATURE SELECT PROGRAMMING METHOD
After entering sections [001] to [016], [126] to [138], and [302] to [348], each option from [1] to [8]
represents a specific feature or option. Press the key corresponding to the desired option and the
corresponding light will illuminate or the option number will appear in the LCD display. This means the
option is on. Press the key again to extinguish the corresponding light or remove the digit from the LCD
display, thereby, turning off the option. Press the [
FORCE] key to set all 8 options to off. Press the keys until
the current section’s options are set. When the options are set, press the [
ENTER] key to save and advance
to the next section.
3.2.3 DATA DISPLAY MODE (LED KEYPADS ONLY)
In the Data Display Mode you can view the programmed contents of each section one digit at a time. After
entering the desired 3-digit section (see step 3 of the shaded box on page 13), press the [
ENTER] key to
access the Data Display Mode (will not function with sections using Multiple Feature Select Programming).
Figure 3.1: Data Display Mode (LED Keypads Only)
3.3 CONFIGURING THE LED KEYPADS
Depending on the version of the keypad, two methods can be used to configure the LED keypads (1686H, 1686V
and 1689):
Table 3:
Decimal and Hexadecimal Programming Table
Value or Action
What Do I
Press?
What Do I See?
10-Zone LED 16-Zone LED LCD
Values 1 to 9 [1] to [9]
[1]
to
[9] [1]
to
[9] [1]
to
[9]
A (hexa only) [0] [0 (10)] [10] 0
B
(hexa only)
[STAY][STAY]
[11] B
C
(hexa only)
[BYP][BYP]
[12] C
D
(hexa only)
[MEM][MEM]
[13] D
E
(hexa only)
[TBL] / [TRBL][TBL]
[14] E
F
(hexa only)
[PG] / [FNC1][PG]
[15] F
Exit Without Saving
[
CLEAR]
[
ENTER] flashes [ARM1] & [STAY1] flash “SECTION [ ]”
Insert Blank Digit
[
FORCE]
Displays next digit or next section
Save Data
[
ENTER]
Advances to the next section