12.3 DISARMING & DEACTIVATING AN ALARM
To disarm an already armed system or to deactivate an alarm, simply key in a valid access code. Program a
designated entry/exit point, such as the front door or the garage door with an Entry Delay Timer. When these entry/
exit point are opened (breached), it will set off a timer. The system will not generate an alarm until this timer elapses,
giving users enough time to enter the premises and disarm the system. Any user can disarm the system, except
users have been assigned the Arm Only Option.
12.4 REGULAR ARMING
This method, commonly used for day-to-day arming, will arm all the zones in the selected partition. If you make a
mistake, the keypad will emit a Rejection Beep. When you have correctly armed the system, the appropriate
ARM
indication will turn on and the Exit Delay will be initiated. Please note that Regular Arming can also be activated
through Auto-Arming, Keyswitch Arming or One-Touch Arming.
12.5 STAY ARMING
This method allows users to remain in the protected area while partially arming the system. For example, when
going to sleep at night, entry/exit points like doors and windows can be armed while other zones like motion
detectors remain deactivated. Please note that Fire Zones cannot be bypassed.
If you make a mistake, the keypad will emit a Rejection Beep. When you have correctly Stay Armed the system, the
appropriate
ARM or STAY indication appears and the Exit Delay is initiated. Stay Arming can also be activated using
Auto-Arming, Keyswitch Arming or One-Touch Arming. The User Code must have the Stay Arming Option enabled.
12.6 INSTANT ARMING
After Stay Arming the system and during its Exit Delay, press and hold the [STAY] key for 3 seconds. You should
hear a Confirmation Beep. This will switch all armed zones to Instant zones.
If you have access to both partitions:
To Instant Arm one partition, press [
STAY] + [ACCESS CODE] + Select Partition + [CLEAR] + press & hold [STAY]
To Instant Arm both partitions, press [
STAY] + [ACCESS CODE] + [1] + [2] + press & hold [STAY]
How Do I Disarm the System or Deactivate an Alarm?
1) Key in your [ACCESS CODE]*
The arm or alarm indication will turn off and the keypad will emit a Confirmation Beep.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the partition you wish to Disarm or to Disarm both partitions, press the [1] key then
after the Confirmation Beep press the [2] key.
How Do I Regular Arm?
1) Green READY indicator must be illuminated. Unless the system is partitioned, in which case all zones in the
desired partition must be closed.
2) Key in a valid [
ACCESS CODE]*
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the partition you wish to arm. To arm both partitions, press the [1] key then after
the Confirmation Beep press the [2] key.
How Do I Stay Arm?
1) All zones in the desired partition (except Stay Zones) must be closed.
2) Press the [
STAY] key
3) Key in a valid [
ACCESS CODE]*
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the partition you wish to Stay Arm. To Stay Arm both partitions, press the [1] key