Sun Microsystems 440 Server User Manual


 
22 Sun SNMP Management Agent Addendum for the Netra 440 Server April 2004
Alarm State Changes
The alarm relay state cannot be changed using SNMP set commands. However, the
alarm relay state can be changed using the Sun Advanced Lights Out Manager
(ALOM) setalarm command. For more information about ALOM commands, refer
to the Sun Advanced Lights Out Manager Software User's Guide for the Netra 440 Server
(817-5481-xx).
The alarm relay states can also be changed using the alarm relay output application
programming interface (API). For information about this API, refer to the Netra 440
Server System Administration Guide (817-3884-xx).
If one of the alarm relays changes its state, the sunPlatAlarmState values associated
with the relay and its corresponding indicator change state, and
sunPlatAttributeChangeInteger traps will be generated in the format shown in
TABLE 11.
TABLE 11 sunPlatAttributeChangeInteger Trap for a Change in the sunPlatAlarmState of an Alarm Relay
or an Alarm Relay Indicator
Variable Value
sunPlatNotificationEventId unique numeric identifier
sunPlatNotificationTime date time
sunPlatNotificationObject entPhysicalDescr.instance
*
* instance indicates the row in the entPhysicalTable associated with the alarm relay or the alarm indicator.
sunPlatNotificationCorrelatedNotifications
sunPlatNotificationChangedOID sunPlatAlarmState.instance
*
sunPlatNotificationOldInteger off(2) or steady(3)
sunPlatNotificationNewInteger off(2) or steady(3)