Sun Microsystems 6900 Series Computer Drive User Manual


 
Appendix A Virtualization Engine References 127
7009A Read degrade recorded. A mirror drive
was written to, causing it to enter the
degrade state.
Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.
7009B Write degrade recorded. If a spare drive is
available, it will be brought in and used to
replace the failed drive.
The removed drive needs to be (if good)
reinserted or (if bad) replaced.
7009C Last primary failed during rebuild. This is
a “multi-point failure” and is very rare.
Backup drive data.
Destroy mirror drive where failure has
occurred.
Format (mode 14) drives.
Create new mirror drive.
Re-assign old SCSI ID and LUN to mirror
drive.
Restore data.
71000 virtualization engine-to-virtualization
engine communication has recovered.
71001 This is a generic error code for the SLIC. It
signifies communication problems between
the virtualization engine and the Daemon.
Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and Daemon server.
Error halt mode also forces this SRN.
71002 This indicates that the SLIC was busy. Check the condition of the virtualization
engine.
Check the cabling between the
virtualization engine and the Daemon
server.
Error halt mode also forces this SRN.
71003 SLIC Master unreachable. Check conditions of the virtualization
engines in the SAN.
71010 The status of the SLIC daemon has
changed.
72000 Primary/Secondary SLIC daemon
connection is active.
72001 Failed to read SAN drive configuration.
72002 Failed to lock on to SLIC daemon.
72003 Failed to read SAN SignOn Information.
72004 Failed to read Zone configuration.
TABLE A-1 SRN and SNMP Reference
SRN Description Corrective Action