Sun Microsystems 6900 Series Computer Drive User Manual


 
Chapter 7 Troubleshooting Virtualization Engine Devices 81
For Internal Use Only
To View the Virtualization Engine Map
The virtualization engine map is stored on the Storage Service Processor.
1. To view the virtualization engine map, type:
Note This example uses the virtualization engine map file, which could include
old information.
# showvemap -n v1 -f
VIRTUAL LUN SUMMARY
Disk pool VLUN Serial MP Drive VLUN VLUN Size Slic Zones
Number Target Target Name GB
---------------------------------------------------------------------------
t3b00 6257334B30303148 T49152 T16384 VDRV000 55.0
t3b00 6257334B30303149 T49152 T16385 VDRV001 55.0
*****
DISK POOL SUMMARY
Disk pool RAID MP Drive Size Free Space T3+ Active Number of
Target GB GB Path WWN VLUNs
-----------------------------------------------------------------------
t3b00 5 T49152 116.7 6.7 50020F2300006DFA 2
t3b01 5 T49153 116.7 116.7 50020F230000725B 0
*****
MULTIPATH DRIVE SUMMARY
Disk pool MP Drive T3+ Active Controller Serial
Target Path WWN Number
-------------------------------------------------------
t3b00 T49152 50020F2300006DFA 60020F2000006DFA
t3b01 T49153 50020F230000725B 60020F2000006DFA
*****
VIRTUALIZATION ENGINE SUMMARY
Initiator UID VE Host Online Revision Number of SLIC Zones
--------------------------------------------------------------------------
I00001 2900006022004195 v1a Yes 08.14 0
I00002 2900006022004186 v1b Yes 08.14 0
*****
ZONE SUMMARY
Zone Name HBA WWN Initiator Online Number of VLUNs
---------------------------------------------------------------------
Undefined 210000E08B033401 I00001 Yes 0
Undefined 210000E08B026C0F I00002 Yes 0