Chapter 1 Getting Started 1-3
1.1.4 Electrical and Environmental
See Appendix B for electrical and environmental requirements.
Caution – None of the integrated chips junction temperature should exceed 125˚C.
The AMC requires air flow to meet this requirement. Testing should be done in the
shelf to find the quantity of air flow needed. The recommended minimum air flow is
50 LFM.
1.2 Unpacking
Check the shipping carton for damage. If the shipping carton or contents are
damaged, notify the carrier and Sun. Retain the shipping carton and packing
material for inspection by the carrier. Obtain authorization before returning any
product to Sun. Refer to the Netra CP3000 Advanced Mezzanine Card PCIe SAS
Controller and Hard Drive Getting Started Guide (820-7177) for return instructions.
Caution – This board must be protected from static discharge and physical shock.
Never remove any of the socketed parts except at a static-free workstation. Use the
antistatic bag shipped with the product to handle the board. Wear a wrist strap
grounded through one of the system's ESD ground jacks when installing or servicing
system components.