Sun Microsystems CP3000 Computer Drive User Manual


 
B-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide March 2010
B.1.3 Absolute Maximum Ratings
The following values are stress ratings only. Do not operate at these maximums. See
Section B.1.4, “Normal Operating Ranges” on page B-4 for normal operating
conditions.
B.1.4 Normal Operating Ranges
*The MTBF will be significantly reduced if operated above 30˚C for more than 96 consecutive hours.
B.2 Reliability
Reliability prediction was done using Telcordia document SR-332, Issue 1. The
prediction assumed 25˚ Celsius operating temperature with 100 percent duty cycle,
in a ground-benign, controlled environment.
MTBF: 630,000 hours
One year limited warranty
Payload voltage, +12V 0 VDC to +13.2 VDC
Management voltage, +3.3V 3.135 VDC to +3.465
VDC
Storage temperature –40 to +70˚ Celsius
Noncondensing relative humidity 5% to 95% at 29˚ Celsius
Description Range
Nominal operating voltage +10.8 to +13.2 VDC payload power
3.135 VDC to +3.465 VDC management
power
Operating temperatures*:
60m below sea level up to 1800m above sea
level
from 1800m up to 4000m above sea level
–5˚ to +55˚C
–5˚ to +40˚C
Operating humidity Less than 85% at 29˚C
Idle power consumption (without links) 9W
Maximum power consumption 12W