Sun Microsystems CP3000 Computer Drive User Manual


 
1-18 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide March 2010
Caution Failure to fill all slots with AMCs or cover with filler panels can
negatively impact the cooling of the system.
9. Power on the system, if necessary.
Refer to your system manual for instructions on correctly powering on the
system. After power is applied to the chassis, the internal MMC controller runs a
self-test that runs for approximately 10 seconds. Upon a successful power up
self-test, the blue Hot-Swap LED will blink and then turn off, indicating that the
module has been placed in operation.
1.7 Enabling and Disabling SAS Ports
As shipped from the factory, the AMC.1-HDD SAS disk will not drive AMC channel
ports, unless specifically enabled. You can individually enable or disable the ports
using lsiutil, a command-line utility supplied by LSI Corporation, and
distributed as part of the software driver distribution. Changes are stored in 32K x
8-bit NVSRAM, located on the module.
To Enable AMC Port 2 (Driven by Port 1 of SAS
Controller)
To Enable AMC Port 3 (Driven by Port 2 of SAS
Controller)
The “-p 1” selects the controller chip. If the AMC.1-HDD SAS disk is the only LSI
controller chip present in the system then the default is controller 1. If there are other
LSI controller chips present in the system, then the user has to determine the proper
controller number.
lsiutil –p 1 –a 13,,,,1,1,,,,,,,,,0,0
lsiutil –p 1 –a 13,,,,2,1,,,,,,,,,0,0