SUPER MICRO Computer 6014L-T Network Card User Manual


 
2-4
S
UPERSERVER 6014L-T User's Manual
Figure 2-1. Identifying the Sections of the Rack Rails
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6014L-T into a rack
unit. If the system has already been mounted into a rack, you can skip ahead to Sec-
tions 2-5 and 2-6. There are a variety of rack units on the market, which may mean
the assembly procedure will differ slightly. The following is a guideline for installing
the unit into a rack with the rack rails provided with the system. You should also
refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6014L-
T. Each of these assemblies consist of two sections: an inner fi xed chassis rail
that secures to the unit (A) and an outer fi xed rack rail (B) that secures to the rail
brackets. A sliding rail guide sandwiched between the two should remain attached
to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached from
each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out.
Do this for both the left and right side rack rail assemblies.
Mounting Holes
A
Locking Tab
B