2-16
LS 3603 Product Reference Guide
• Power Mode
This parameter determines whether or not power remains on after a decode
attempt. When in low power mode, the scanner powers down after each
decode attempt. When in continuous power mode, power remains on after
each decode attempt. To ensure the integrity and proper operation of this
product, it is recommended that the low power mode be set for RS-232C and
Wand modes, and continuous power mode for Synapse mode.
• Scanstand/IntelliStand Time-out
Scanstand/IntelliStand operation can be programmed to shut down if no bar
code is detected within the specified time. Duration is programmable in 15
minute increments from 15 minutes to 90 minutes.
•Wand Emulator Options
Wand Emulator Bar Output
The polarity of the wand emulator output is set automatically when the
Wand Host type is selected. This parameter can be used to change the default
polarity setting to match the type of signal (bar = logic high, or bar = logic
low) expected by the receiving system
Variable Leading Margin
This parameter allows the selection of a variable leading margin, ranging from
80 msec to 200 msec, in 10 msec increments.
Convert All to Code 39
This parameter converts the output of all data to Code 39 format. Any coded
character not in the Code 39 character set is replaced by a Code 39 blank.