6-4
LS 9208 Product Reference Guide
RS-232 Host Parameters
Various RS-232 hosts are set up with their own parameter default settings (Table 6-2).
Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron,
or terminal sets the defaults listed below.
Table 6-2. Terminal Specific RS-232
Parameter
Standard
(Default) ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/
OPOS Olivetti Omron
Transmit Code ID No Yes Yes Yes Yes Yes Yes
Data
Transmission
Format
Data as is Data/
Suffix
Data/
Suffix
Data/Suffix Data/Suffix Prefix/Data/
Suffix
Data/Suffix
Suffix CR/LF
(7013)
CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013)
Baud Rate 9600 9600 9600 9600 9600 9600 9600
Parity None Even None Odd Odd Even None
Hardware
Handshaking
None RTS/CTS
Option 3
None RTS/CTS
Option 3
RTS/CTS
Option 3
None None
Software
Handshaking
None None None None None Ack/Nak None
Serial Response
Time-out
2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec.
Stop Bit Select One One One One One One One
ASCII Format 8-Bit 8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit
Beep On <BEL> Disable Disable Disable Disable Disable Disable Disable
RTS Line State Low High Low Low Low = No
data to send
Low High
Prefix None None None None None STX (1003) None
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan
bar codes.
**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear
unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power
to the scanner.