Appendices
315
Cable Specification
RS-530/RS-366
TANDBERG MXP and Classic Endpoints that support External
Network
• Connector on Tandberg End:
o Female 26pin High Density DSUB Newark P/N 50F2055 or Equivalent
• Connector on RS-530:
o DSUB 25 pin Male
• Connector on RS-366:
o DSUB 25 pin Male
• Cable length:
o 1 meter
Signal Name Female
26pin
DSUB
(Tandberg
end)
Pin
Number
Male
25pin
DSUB
RS-530
(DCE end)
Pin
Number
Male
25pin
DSUB
RS-366
Pin
Number
Comments
Frame Ground 1 1
Do not connect shield to FGND
Signal Ground 19 7
Send Data (A)
Send Data (B)
11
12
2
14
Twisted Pair
Send Timing (A)
Send Timing (B)
17
18
15
12
Twisted Pair
Receive Data (A)
Receive Data (B)
13
14
3
16
Twisted Pair
Receive Timing(A)
Receive Timing (B)
15
16
17
9
Twisted Pair
Terminal Ready(A)
Terminal Ready(B)
20
21
20
23
Receiver Ready (A) 22 8
Twisted Pair
Receiver Ready (B) 23 10 Twisted Pair
LOS A 25 18
LOS A Unbalanced
RS366 DPR 2 2
RS366 ACR 3 3
RS366 CRQ 4 4
RS366 PND 5 5
RS366 DLO 6 22
RS366 NB1 7 14
RS366 NB2 8 15
RS366 NB4 9 16
RS366 NB8 10 17
RS366 GND 1 7