TANDBERG ENTRYPOINT Network Card User Manual


 
D 14050.04
10.2007
48
TANDBERG ENTRYPOINT
USER GUIDE
Table of
Contents
Trademarks &
Copyright
Patents &
Disclaimers
Safety/
Environmental
To Get You
Up and Going
Using the
Entrypoint
Viewing the
System Status
Configuring
the Entrypoint
Maintenance
& Upgrade
Services
Dial Plan
Examples
Contact
Information
Dial Plan
Examples
TANDBERG ENTRYPOINT
USER GUIDE
Dial Plan Examples
Given the supported net types, H.324m, H.323
and SIP, 9 unique inbound and outbound net
type combinations for both DID and IVR dial
plans can be defined
Some of these combinations will be discussed
in a few examples.
Example 1: Number-plan mapping
Entry details: Enabled: Check
Name: H.324m-H.323
Net Type: H.324m
Prefix: 6789
Suffix: Service: Direct Inwards Dialling
Arguments: Net Type: H.323
A V Mode: Auto + fallback to audio
Prefix: 5
Suffix: Use Remainder: Yes
Allow Forwarding: No
When dialling the number 67890000 there will be a match with
“0000” as the remaining number. The H.323 number that will be
connected to will be: 50000 (construction: Prefix + Use remainder
number). When dialling number 67894321 this will match with
“4321” as the remaining number. The H.323 number to call will be:
54321. In this way a range of ISDN numbers can be mapped onto
for instance a range of H.323 numbers.