Telect BCS II Network Card User Manual


 
BCS II Simplex Repeater User Manual 2 Installation
117209-1 A0
2-5
6. Slide each module into the appropriate chassis slot and press it
firmly into the backplane connector.
7. Secure each module with the included screw.
8. Follow the diagram below to connect two network elements.
9. Install backplane tracer lamp wire between the two repeaters and
verify both tracer lamp LEDs light.
10. Install designation strips and label them using office standards.
11. Test circuits per office standards.
Simplex Repeater
LBO Settings
CABLE
Repeater
to NE
distance
(feet)
FIGURE
Distance
Transmit
LBO
Setting
Repeater
to
Repeater
distance
(feet)
FIGURE
Distance
Receive
LBO
Setting
0-124 A or C SHORT 0-124 B SHORT
124-255 A or C LONG 124-255 B LONG
0-212 A or C SHORT 0-212 B SHORT
212-425 A or C LONG 212-425 B LONG
0-224 A or C SHORT 0-224 B SHORT
224-450 A or C LONG 224-450 B LONG
0-112 A or C SHORT 0-112 B SHORT
112-225 A or C LONG 112-225 B LONG
0-224 A or C SHORT 0-224 B SHORT
224-450 A or C LONG 224-450 B LONG
RG-59
720
728
734
735
NE
NE
TX
RX
TX
RX
SIMPLEX
REPEATER
710-3201-0002
AB
Distance Distance
O
I
I
IX
OX
O
O
I
O
I
OX
IX
SIMPLEX
REPEATER
710-3201-0002
Distance
C
Each network element can be located up to 900ft. from the far end repeaters IX port.
(using RG-59/734)