Loopback Control Switch
The front panel of the modem has a push button for initiating the
following loopback diagnostic tests:
c
Local analog loopback
started by pressing the button one time.
c
Local digital loopback
started by pressing the button two times.
c
Remote digital loopback
set the local modems RTS signal to
low. Then press the remote modems diagnostics button three times
and raise the local modems RTS signal to start the test. The
ALB
and
DLB
LEDs go ON when the modem is in remote digital
loopback. This test is only available in Fast Poll mode only.
Figure 2-6 illustrates these three diagnostics.
Figure 2-6. Loopback Diagnostics