Toshiba EO1-33057 Barcode Reader User Manual


 
APPENDIX 1 MESSAGES AND LEDS ENGLISH VERSION EO1-33057
APPENDIX 1 MESSAGES AND LEDS
EA1- 2
LED Indication
No. LCD Message
POWER
ON
LINE
ERROR
Printer Status
Restoration by
RESTART ke
y
(Yes/No)
Acceptance of
Status Request
Reset Comman
d
(Yes/No)
21 SYSTEM ERROR z
When the following abnormal operations
are performed, a system error occurs:
(a) Command fetch from an odd address
(b) Access to word data at an odd address
(c) Access to long-word data at an odd
address
(d) Access to the area of 80000000H to
FFFFFFFFH in the logic space in
user mode.
(e) An undefined instruction in an area
other than a delay slot was decoded.
(f) An undefined instruction in a delay
slot was decoded.
(g) An instruction to rewrite a delay slot
was decoded.
No No
22
100BASE LAN
INITIALIZING…
z z
100 Base LAN Board is being initialised. ----- -----
23
DHCP CLIENT
INITIALIZING…
z z
The DHCP client is being initialized.
*When the DHCP function is enabled.
----- -----
24 LOW BATTERY z
The voltage of the Real Time Cloc
k
Battery is 1.9V or less.
No Yes
25 RFID WRITE ERROR
z
The printer did not succeed in writing data
onto an RFID tag after having retried for a
specified times.
Yes Yes
26 RFID ERROR
z
The printer cannot communicate with the
RFID module.
Yes Yes
NOTE: When an error message listed above appears on the LCD message display, please refer to Section 5