Toshiba IK-CU44A Webcam User Manual


 
17
1
Move the cursor to LINK using the UP or DOWN
button.
3 Move the cursor to a desired item (H-PHS, SC-
PHS, SC-FINE) using the UP or DOWN button.
Press the FUNC button and the data is displayed.
Set the data using the UP or DOWN button and
press the FUNC button to select the data. To re-
turn to the main menu, move the cursor to EXIT
and press the FUNC button.
Note:
If the internal synchronization is set while
the SYNC item (H-PHS, SC-PHS, SC-FINE) is
being displayed, the display automatically
turns to INT, disabling setting.
SHUTTER
FILE
PEDESTAL
SYNC H-PHS
AREA SC-PHS
W
B-OFFSET SC- FINE
EXIT
INIT.
END
PUSH FUNC TO SELECT
50
0
50
7.5
AREA (Measurement Area)
AREA is a measurement AREA item for AGC, auto
electronic shutter and white balance. The AREA set-
ting for AGC and auto electronic shutter are the
same, so each setting can not be made separately.
However, the AREA setting for white balance can
be made independently from the AREA setting for
AGC and auto electronic shutter.
1
Move the cursor to AREA using the UP or DOWN
button.
2
Press the FUNC button to display the available
items (LINK, SEP).
3
Move the cursor to a desired item (LINK, SEP)
using the UP or DOWN button.
(1) Setting AREA the same for AGC, auto electronic shutter and
white balance
SHUTTER
FILE
PEDESTAL
SYNC
AREA LINK:1
W
B-OFFSET SEP
EXIT
INIT.
END
PUSH FUNC TO SELECT
SHUTTER AUTO
FILE A
PEDESTAL 00
SYNC INT
AREA LINK:1
W
B-OFFSET 00
INIT.
END
PUSH FUNC TO SELECT