4. CONNECTION
4.1 An Example of Standard Connection
4.2 Cautions on Connection
When connecting or disconnecting the camera cables (for the camera head and
camera control unit), always turn off the power switch of the camera control unit
first. If not, the camera head may be damaged.
When connecting the camera, always turn off the power of the camera control
unit and any other equipment connected.
1
Remove the camera head protection cover and mount a lens (option).
2
Connect the camera head and the camera control unit with the camera cable
(option).
3
Connect the VIDEO (or S-VIDEO) terminal of the camera control unit to a video
input terminal of a monitor, etc.
4
Connect a DC power supply (12V) to the DC IN 12V terminal of the camera control
unit.
For DC power supply connecting to DC IN 12V terminal, use UL listed and/or CSA
approved ungrounding type AC adaptor with the specifications described below.
Power supply voltage: DC12V ± 0.5V
Current rating: More than 800 mA
Ripple voltage: Less than 50 mV(p-p)
Connector: HR10A-7P-4S (Hirose)
Pins 1, 2: , Pins 3, 4:
Lens
(Option)
Camera
head (Option)
Camera control unit
Camera cable
(Option)
Monitor
CAMERA
VIDEO
DC IN 12V
DC power supply
DC 12V