Toshiba MA-1450-1 SERIES Cash Register User Manual


 
6. PROGRAMMING OPERATIONS
EO1-11095
6-17
-- Continued --
6.8 PLU TABLE PROGRAMMING (Submode 4)
Address No. Description of Programming Contents
10 Link-PLU Table No. (for PLU-to-PLU linking requirement only)
This entry is useful, when the PLU item entry should always be followed by another PLU
item sale. If the PLU is not applied to this case, skip this address entry. Refer to the
following examples of applications:
HEAD-LINK PLU SUB-LINK PLU
Example 1) PLU1: Coca-Cola PLU2: Bottle
Small Bottle Deposit for the
Net Content small bottle
at $0,45 at $0,05
Example 2) PLU 101: Battery- PLU 202: Battery
drive Clock Pack at $1,50
at $20,00
As shown in the examples, this feature prevents the cashier from forgetting to enter the Sub-
link PLU item attached to the Head-link PLU item.
And at the same time, in reports, two PLU Totals are separately read.
In setting, enter the Link-PLU Table No. (1 to 99) and then depress [#].
| | | [#]
To cancel the sub-linking, enter 0 instead of the Link-PLU Table No. before [#].
REMARKS:
1) When the Head-link PLU is entered in a sale, the Sub-link PLU will automatically be
entered. When the Sub-link PLU is an open-price PLU, the price entry and the
[AMT] key depression should follow manually on the main keyboard.
This manual operation sequence cannot be replaced by a PLU Preset-code Key on
the main keyboard or on the PK-2 keyboard.
2) The PLU-to-PLU linkage is effective even when the Head-link PLU is an open-price
PLU.
3) The linkage is effective in a sale only for one Head-link PLU and one Sub-link PLU.
If the Sub-link PLU is further programmed with another Sub-link PLUs (with a Link-
PLU Table No.), the third PLU will not automatically entered.
4) It is possible to set multiple PLUs as Head-link to one Sub-link PLU. (In Example 1
described above, it may be extended to have more Head-link PLUs of similar items
such as 7-up, which also link to the Bottle Deposit of the same amount.)
5) Repeat, Item Correct, Dollar Discount, Vendor Coupon, Bottle Return, %+, or %-
operations are not accepted for PLU-to-PLU link entries. But Return Merchandise
or Void operation is possible for the Head-link (and the Sub-link PLU will be
processed as returned or voided item automatically, in this case).
6) The Sub-link PLU may be operated for sales entries, skipping the Head-link PLU,
without affecting the Head-link PLU sales memory.
7) Multiplication is possible on the Head-link PLU, and then the Sub-link PLU will
automatically be multiplied with the same quantity.
8) Modifier Keys (such as [SI/M]) will be effective for the Head-link PLU item only, and
the modification will be disregarded for the Sub-link PLU.
9) When an error occurs at the Sub-link PLU, only the Head-link PLU is entered but
not the Sub-link PLU. (Errors such as Multiplication Product Over-limit Error, the
Sub-link PLU has not been opened, the sale subtotal will turn into negative, etc.)
1 to 99 (Link-PLU Table No.) The Sub-link PLU which link to the Link-PLU
Table will be programmed in a separate programming operation later.
-- Continued on next page --