Toshiba TDP-ET10 Projector User Manual


 
53
Others
Trouble indications
The indicator lights inform you of internal abnormalities.
LED indicators State/Problems
No LED lit
No power
Problem with projector
• Unplug the power cord, and contact your dealer.
The lamp cover is not properly attached.
• Unplug the power cord, and reattach the lamp cover.
Red LED is fl ashing at ON/
STANDBY indicator (2Hz)
Power went out during use
Internal overheating, or the outside temperature is too high.
Place the projector so that the air intake and exhaust are not
blocked.
• Unplug the power cord and wait for a short while, then turn
the power back on.
The icon will appear before the power goes out.
After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.
Red LED is fl ashing at ON/
STANDBY indicator (5Hz)
Power went out during use
Problem with internal cooling fan.
• Unplug the power cord, and contact your dealer.
The icon will appear before the power goes out.
After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.
Red LED lit at ON/STAND-
BY indicator
Power went out during use, or won’t come on
Lamp temperature is high so that it is diffi cult to turn on,
the lifetime of the lamp has ended or the projector is
malfunctioning.
Unplug the power cord and wait for a short while, then turn
the power back on.
If a lamp burns out, replace it with a new one.
After approx. one minute of abnormal display, the projector
returns to the standby state waiting for internal cool down.