2.5 2.5-inch HDD 2 Troubleshooting
Procedure 4 Test Program Check
Run the HDD test program stored on the maintenance test program disk for all test items.
See Chapter 3 for details on how to use the test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and their status names are listed in Table 2-1. If an error code is not generated
and the problem still exists, go to Procedure 5.
Table 2- 1 HDD error code and status
Code Status
Get Parameter Fail !
1
2
Read Old Data Error
Write Pattern Error
3
4
Read Back Data Error
Data Compare Error
5
Restore Data Error
6
Read Verify Error
7
9
Seek Error
10
Disk Controller Self Test Failed
11
Disk Controller Test unexpected interrupt Failed
Disk Controller action Test Failed
12
Disk dos not support SMART
13
Disk read attribute threshold error
14
15
Disk read attribute value error
16
Disk SMART attribute value error