Transition Networks SISTF10xx-130-LR(T) Switch User Manual


 
12
SISTF10xx-130-LR(T)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model SISTF10xx-130-LR(T) or equivalent
Standards: IEEE 802.3™, 802.3u™; 802.3x™
Data Rate: 10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber)
Processing Type: Store and Forward
w/ IEEE802.3x™ full-duplex, non-blocking flow control
Dimensions: 1.8" x 5.3" x 4.1" (46 mm x 135 mm x 105 mm)
Weight: 1.4 lb. (0.65 kg) (approximate)
Input Power: 12-48VDC, 0.2-0.7A, 24W (minimum), (redundant inputs)
with overload and reverse polarity protection
Address Table Size: 1,000 Unicast Mac addresses
Alarm Relay: 1 Amp @ 24 VDC
Mechanical: Ingress Protection: IP30
Environment: Tmra* (standard temp): 0 to 60°C (32 to 140°F)
Tmra* (extended temp): -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 5 to 95%, non condensing
Warranty: Lifetime
*Manufacturer’s rated ambient temperature.
The information contained in this user’s guide is subject to change. For the most
up-to-date information see the user’s guide on line at: www.transition.com.
This device is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not
stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of
procedures other than those specified herein may result in hazardous
radiation exposure
CAUTION: This device is intended to be supplied by a listed power unit
marked LPS or Limited Power Source, provided with a connector for field
wiring terminal, and output rated 12-48VDC, 0.2-0.7 A, 24 W minimum.
CAUTION: This device is designed for operation with a safety extra-low
voltage (SELV) in compliance with IEC950 / EN60950 / VDE0805 and in
compliance with the low voltage directive 73/23/EEC and 93/68/EEC.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
13
Test Description Test Levels
IEC 60068-2-6 Vibration 10 - 500 - 10 Hz, 0.5 oct./min, 4g, X, Y, Z (3 axes)
IEC 60068-2-27 Shock 50 g, 11 ms, +/-X, +/-Y, +/- Z (6 direction)
IEC 60068-2-32 Free fall 75 cm, 1 corner, 3 edges, 6 faces (total 10 drops)
Environmental Type Tests
Test Description Test Levels Severity
IEC61000-4-2 ESD Air discharge +/- 8 KV 3
Contact discharge +/- 6 KV 3
ESD contact discharge +/- 6 KV 3
IEC61000-4-3 Radiated RFI Housing 10V/m, 80 MHz - 1 GHz
AM 1 KHz, 80% mod
10 V/m, 0.9 - 1.8 GHz
FM 200 Hz 50% square
3
IEC61000-4-4 Burst
(Fast Transient)
Power supply lines +/- 2 KV 3
Communication lines +/- 1 KV 3
Relay +/- 1 KV 3
IEC61000-4-5 Surge Power supply lines +/- 2 KV, 12 , CM
+/- 1 KV, 2 , DM
3
Relay +/- 2 KV, 12 , CM
+/- 1 KV, 2 , DM
3
IEC61000-4-6 Induced
(Conducted RFI)
Power supply lines 10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
Communication lines 10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
Relay 10 Vrms, 150-80 MHz
AM 1 KHz, 80% mod
3
Technical Specifications -- Continued
EMS Type Tests