Transition Networks SISTF10xx-130-LR(T) Switch User Manual


 
14
SISTF10xx-130-LR(T)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Troubleshooting
If the device fails, isolate and correct the fault by determining the answers to the
following questions and then taking the indicated action:
1. Is the PWR1 LED illuminated?
NO
Ensure the power source is the proper voltage (12 - 48 VDC).
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR1”.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 2.
2. Is the PWR2 LED illuminated?
NO
Ensure the power source is the proper voltage (12 - 48 VDC).
Ensure the (+) and (-) wires from the power source are inserted
properly in the terminal block contacts labeled “PWR2”.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the FAULT LED illuminated?
YES
If one or more port alarm switches (1 - 5) is ON
, the device lost the
corresponding fiber or copper link; or primary or backup power.
Ensure the problem copper or fiber link is properly connected.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
Proceed to step 4.
4. Is the Ring Master LED flashing?
YES
A link in the Redundant Ring is broken. Inspect the fiber links in the
ring for proper connection.
Verify that the TX and RX cables on one device are connected to the
RX and TX ports, respectively, on the adjacent device.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
Proceed to step 5.
5. Are either 100M LEDs (near the fiber links) illuminated?
NO
Check the corresponding fiber cables for proper connection.
Verify that the TX and RX cables on the device are connected to the
RX and TX ports, respectively, on the other device.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 6.
Troubleshooting -- Continued
6. Are either 100M LEDs (near the fiber links) flashing?
NO
If there is activity on the corresponding fiber port, disconnect and
reconnect the fiber cable to restart the initialization process.
If there is no activity on the corresponding fiber port, contact Tech
Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 7.
7. Are any of the 10M LEDs (on the RJ-45 port) illuminated?
YES
The device has selected 10 Mb/s for the twisted-pair link.
If the speed is not correct, disconnect and reconnect the twisted-pair
cable to restart the initialization process.
Proceed to step 8.
NO
Proceed to step 8.
8. Are any of the 100M LEDs (on the RJ-45 port) illuminated?
YES
The device has selected 100 Mb/s for the twisted-pair link.
If the speed is not correct, disconnect and reconnect the twisted-pair
cable to restart the initialization process.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
NO
Check the twisted-pair cables for proper connection.
Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
15
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344, USA
Model: SISTF10xx-130-LR(T) Series Redundant Ring Industrial Switches
Part Number(s): SISTF1011-130-LR, SISTF1012-130-LR, SISTF1013-130-LR,
SISTF1014-130-LR, SISTF1011-130-LRT, SISTF1012-130-LRT,
SISTF1013-130-LRT, SISTF1014-130-LRT
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
SISTF10xx-130-LR(T)
to which this declaration refers
is in conformity with the following standards.
EN 55022:1998 Class A; FCC Part 15 Subpart B; 21CFR subpart J;
UL 60950; UL 508; CSA C22.2 no 60950; EN 60950;
UL/cUL Class 1, Div 2, Groups A, B, C, D; ATEX Class 1, Zone 2, EExnC IIC;
EN61000-4-2, -4-3, -4-4, -4-5, -4-6; IEC 60068-2-6, -2-27, -2-32
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
_December 3, 2004_____
Stephen Anderson, Vice-President of Engineering Date
NOTE: The following part numbers are UL listed: SISTF1013-130-LR, SISTF1013-130-
LRT, SISTF1014-130-LR, SISTF1014-130-LRT