Transition Networks SISTG10xx-111-LR(T) Switch User Manual


 
SISTG10xx-111-LR(T) Industrial Media Converter Transition Networks
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
11
Grounding the Media Converter
CAUTION
Be sure to disconnect the Media Converter from the DC power source before installing
and wiring the device.
Wiring
considerations
The following wiring considerations are recommended:
Signal lines must not be directly connected to outdoor wiring.
Use separate paths or conduits to route wiring for power and device data cables. To avoid
interference, wires with different signal characteristics route separately. If power wiring and
device data cables must cross make sure that the wires are perpendicular at the
intersection point.
Use the type of signal transmitted through a wire to determine which wires should be kept
separate. The rule of thumb is wiring that shares similar electrical characteristics can be
bundled together.
Keep input and output wiring separated.
CAUTION
The Media Converter is intended to be grounded to a well-grounded mounting surface
such as a metal plate. Install the grounding wire prior to connecting any other device to
the Media Converter.
Media Converter
grounding
Grounding the Media Converter helps limit the effects of noise due to electromagnetic
interference (EMI) via proper grounding. Always run the ground connection from the ground
screw to a grounding surface before connecting the Media Converter to a DC power source.
See Figure 7.
Figure 7: Industrial Media Converter Ground Screw (Top Panel)