Transition Networks SISTG10xx-111-LR(T) Switch User Manual


 
Transition Networks SISTG10xx-111-LR(T) Industrial Media Converter
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
20
DIP Switches
DIP switch
position
descriptions
The Media Converter features two DIP switches on the front panel used to configure the
Media Converter for use in a particular network setting. Figure 18 shows the DIP switches
and a chart that explains each setting.
No Description Default
1
Power Alarm
(enable ON, disable OFF)
If either PWR1 or PWR2 input fails, the fault
LED will light up and the alarm contacts will
open
OFF
2
Link Pass Through
(enable ON, disable OFF)
See Advanced Features, Page xx
OFF
Figure 18: Dip Switch Settings and Explanations
CAUTION
DIP switch changes will not become active until the Media Converter is power cycled
(turned OFF then ON).
ON
1 2
ON