3.5 Connecting Units to Power
The StackMaster™TR 16-Port Stack is connected to power by connecting
each of the StackMaster™TR 16-Port Units to power.
NOTE: Connect StackMaster™TR 16-Port Units from bottom to top.
To connect the StackMaster™TR 16-Port Stack to power:
1. At StackMaster™TR 16-Port Unit back, locate the Unit power
receptacle and associated fuse.
NOTE: Fuse must be installed at correct setting for power source voltage
before connecting to AC outlet.
2. Verify that fuse is installed at correct setting for power source
voltage.
NOTE: The installed fuse rating is indicated by the reading at lower right
corner of fuse holder.
If not installed at correct setting for power source voltage:
Carefully open fuse receptacle, using a small flat blade
screwdriver.
Rotate fuse holder 180° to the correct rating orientation.
Install fuse holder in correct rating orientation.
Close fuse receptacle.
3. Plug unit end (female) of power cord into StackMaster™TR 16-
Port Unit power receptacle.
4. Plug outlet end (male) of power cord into correct voltage AC wall
socket.
5. At StackMaster™TR 16-Port Unit front, verify that POWER LED is
illuminated.
6. Repeat steps 1 through 5 until all StackMaster™TR 16-Port Units
have been powered.
StackMasterTR
3-6
110-120
110-120
220-240
220-240
110-120 Orientation 220-240 Orientation
Fuse Holder Fuse Holder