3. Select RAID0, then press Enter.
4. Select the number of drives then press Enter.
5. Select Auto configuration, then press Enter.
6. Input the RAID size, press Enter.
7. When asked Are You Sure (Y/N)?, press Y to accept.
8. Press Ctrl+E to exit the BIOS.
9. When asked Are you sure to exit (Y/N)?, press Y to exit
and reboot.
10. Continue with FDISK and FORMAT steps as if you were
installing a conventional hard drive.
Manual configuration
1. As the BIOS boots press Ctrl+S or F4 when prompted to
enter the RAID BIOS.
2. At the next screen select Create RAID Set, then press
Enter.
3. Select RAID0, then press Enter.
4. Select the number of drives then press Enter.
5. Select Manual configuration then press Enter
6. Select chunk size from 8k, 16k, 32k, 64k or 128k, then
press Enter.
7. Select the first drive, press Enter.
8. Select the second drive, press Enter.
9. If applicable select the 3rd
and 4th drives pressing enter
after each selection.
10. Input the RAID size, press Enter.
11. When asked Are You Sure(Y/N)?, press Y to accept.
12. Press Ctrl+E to exit the BIOS.
13. When asked Are you sure to exit(Y/N)?, press Y to exit
and reboot.
14. Continue with FDISK and FORMAT steps as if you were
installing a conventional hard drive.