Installation
Vidikron Vision Model 110 Owner’s Operating Manual 37
PRE
L
IMINAR
Y
3.8
Turning on the Power
1. Turn on your source components.
2. If this is an AutoScope-equipped projector, turn on the main power switch at the rear of
the AutoScope lens motor. The lens motor power switch is located next to the AC input
(see
Figure 3-16).
3. Press the ON button on the remote control – or the SOFT PWR button on the projector
rear panel – to turn on the system. The vacuum fluorescent display on the projector rear
panel briefly displays “Starting Display.”
4. When the projector is ready for use (after about 20 seconds), the RUN LED on the
projector rear panel lights solid blue. The fluorescent display indicates the current input
source, aspect ratio and input resolution; for example:
3.9
Adjusting the Picture
Orientation
By default, the Vision 110 is configured for a “floor/front” installation, in which the projector is
installed upright and in front of the screen. If it is installed behind the screen and/or inverted,
you must change the picture orientation. To do this:
1. Press MENU.
2. Select Service from the Main Menu and enter the Service Menu passcode.
3. Select Display Device from the Service Menu.
4. Select Installation from the Display Device menu.
5. Choose Floor Rear, Ceiling Front or Ceiling Rear, to match the installation method.
V110 Component RCA
16:9 480I
Current Input Source
Aspect Ratio Input Resolution
You must enter a passcode to access the Service menu.
Note