VXI CT-100C Series Six-Slot VXIBus Chassis Network Hardware User Manual


 
VXI Technology, Inc.
18 CT-100C Introduction
POWER SPECIFICATIONS
USEABLE POWER
500 W to 50 °C, derated by 2.5%/ °C above 50 °C
DC SUPPLY VOLTAGE
Voltage
Peak
Current
(I
MP
)
Dynamic
Current
(I
MD
) Allowed Variation
Ripple/Noise
DC Load
Induced
Ripple
Noise
+5 V 40 A 5 A +0.25 V / -0.125 V 50 mV 50 mV
-5.2 V 10 A 5 A -0.26 V / +0.125 V 50 mV 50 mV
-2 V 8 A 2 A -0.10 V / +0.72 V 50 mV 50 mV
+12 V 8 A 2 A +0.60 V / -0.36 V 50 mV 50 mV
-12 V 4 A 2 A -0.60 V / +0.36 V 50 mV 50 mV
+24 V 4 A 2 A +1.20 V / -0.72 V 150 mV 150 mV
-24 V 4 A 2 A -1.20 V / +0.74 V 150 mV 150 mV
POWER INPUT
Input Voltage / Freq.
Nominal AC
Inrush Current
Input Power
Input Leakage
Input Harmonics
Fuse
Minimum 100 V ac to a maximum 240 V ac, 50 Hz/60 Hz
< 40 A (cold start)
10 A max
< 1.24 MA @ 264 V ac, 53 Hz
Meets EN61000-3-2
Internal and independent of line voltage (not user accessible)
POWER SUPPLIES
UL, CSA, TUV approved, CE marked
Shout circuit, over-voltage, reverse voltage and thermal shutdown protection
COOLING SPECIFICATIONS
COOLING REQUIREMENTS*
Low Fan Speed
High Fan Speed
56 W/slot for a 10°C Rise
84 W/slot for a 15°C Rise
80 W/slot for a 10°C Rise
120 W/slot for a 15°C Rise
*Calculated using VXI-8 Rev. 2.0 standards
COOLING MODES
High or low speed cooling modes can be selected by moving the Fan Speed
switch at the rear of the chassis. The power supply and modules are cooled by
separate fans.
AIR FLOW PATH
Air is drawn into the chassis from the rear and is pressurized below the cards.
The air is then distributed across all slots along the total length of each slot and
is exhausted through the top of the mainframe. When the mainframe is rack
mounted, allow approximately 2 inches (50 mm) of clearance at the top and rear
for proper airflow.
ACOUSTIC NOISE
High Speed Fan Mode < 40 dBA
Low Speed Fan Mode < 30 dBA