Wasp Bar Code WPL606 Printer User Manual


 
4. Calibration
There are two power-on button combinations to initialize the printer settings
and to calibrate sensors on the W606.
4.1 Printer Initialization
Printer Initialization will restore printer settings to defaults. Do this if labels are
printing incorrectly and all other solutions have failed to solve the problem.
Default settings:
Item Default Value
Cleared by
Initialization
Property Saved
when Turning off
Power
Mileage N/A No Yes
Check Sum N/A No Yes
Serial Port 9600,n,8,1 Yes Yes
Code Page 850 Yes Yes
Country Code 001 Yes Yes
Tear Mode On Yes Yes
Peel Mode Off Yes Yes
Cutter Mode Off Yes Yes
Offset 0 Yes Yes
Reference Point 0,0 Yes Yes
Print Direction 0 Yes Yes
Speed 4 IPS Yes Yes
Density 08 Yes Yes
Label Size 3”x3” (77X77mm) Yes Yes
Gap/Bline Sensor Gap Sensor Yes Yes
Gap(Bline) 0.12” (3 mm) Yes Yes
Transparency 17 Yes Yes
Ribbon Sensor
Sensitivity
1 Yes Yes
LCD Language English Yes Yes
Aux. LED Off Yes Yes
Aux. Buzzer Off Yes Yes
Download Files N/A No Yes
RTC N/A No No