To initialize the printer:
1. Turn off the printer power
2. Hold down the PAUSE and FEED buttons and turn on the printer power
3. Release the buttons once the Power, On-Line, and Error lights are lit
Note: The printing method, thermal transfer or direct thermal printing, will be
set automatically at the activation of printer power by checking for the
ribbon. If there is no ribbon the printer will go into direct thermal printing
mode.
Note: When printer initialization is done, please calibrate the gap sensor
again.
4.2 Gap/Black Mark Sensor Calibration Utility
The gap/black mark sensor must be calibrated whenever the label media
changes or after printer initialization.
To calibrate the Gap/Black Mark Sensor:
1. Install the ribbon and label roll as the above-mentioned procedures, and
engage the print head lift lever.
2. Turn off printer power.
3. Hold down the PAUSE key and then turn on printer power. Release the
PAUSE key when “GAP/BLINE sensor calibrating….” message is shown
on the LCD display. The printer will calibrate the gap/black mark sensor