Xantrex Technology ENET-XFR3 Power Supply User Manual


 
Operation
3–22 TM-XR9B-01XN
Able to connect to
the device server
(Ethernet Bridge),
but unable to
control or receive a
response from the
power supply
The Ethernet/RS-232
Interface card is configured
for RS-232 communications
The embedded Ethernet
Bridge is incorrectly
configured
Reconfigure the interface card for Ethernet
communications. See page 2–12 for details.
Ensure that the baud rate for the Ethernet Bridge
is set for 9600 by connecting to its HTTP server
and checking its Serial Port settings. This can be
done by entering the device's IP address into a
web browser and using the correct username and
password to access the device server. See
“Configuring Ethernet Bridge” on page 2–15 for
more information.
Ensure that the baud rate setting on the interface
card is set to 9600 - see the “Baud Rate
Selection” on page 2–18 for details.
Table 3-10
Ethernet Mode Tips
TM-XR9B-01XN.book Page 22 Monday, April 19, 2004 9:00 AM