Xantrex Technology RS2000 Tablet Accessory User Manual


 
Operation
975-0125-01-01 2–11
Hibernate mode
Characteristics Hibernate mode removes network power from the System Control Panel
and all Xanbus-enabled devices on the Xanbus system. The System
Control Panel suspends all operations (including starting and stopping the
generator) until power is restored to the network. All Xanbus-enabled
devices other than the RS2000 have no network power.
When to use Use Hibernate mode when the Xanbus system is left unattended for long-
periods of time to prevent any unattended system activity and to prevent
battery drain during long periods of inactivity.
The system will automatically enter Hibernate mode if it is in Power Save
mode for more than two hours.
If there are active faults in the system, you cannot force the system into
Hibernate mode. Clear any active faults, correct the condition that caused
the fault, then put the system into Hibernate mode. The RS2000 can enter
hibernate mode with an active fault.
Restoring power Once in Hibernate mode, the System Control Panel cannot return the
System to Operate mode. You must restore power to the network by
pressing the Reset button on the RS2000 front panel for several seconds.
If an inverter/charger supplies power to the network, you can bring the
system out of Hibernate mode either by pressing the reset button on the
inverter/charger front panel or by applying AC input with utility power or
generator power.
Important:
To prevent any unattended system activity, put the system into
Hibernate mode from the System Control Panel before putting your RV or boat
into storage.