Xantrex Technology RS2000 Tablet Accessory User Manual


 
Configuration
3–2 975-0125-01-01
General Configuration Information
System Control
All changes to the configuration of the RS2000 are made with the System
Control Panel (SCP). The System Control Panel provides configuration
and monitoring capability for all Xanbus-enabled devices on the network.
The front panel of the RS2000 provides limited control, including reset;
charger enable and disable; and inverter enable and disable. When a
function is disabled, it is not allowed to occur and if it is occurring, it is
terminated. Regardless of other conditions, the function will not be
activated. For example, even if AC power is present, if the charger is
disabled, the unit will not charge.
When a function is enabled, it is allowed to occur but other conditions
may have to be met before the function is activated or turned on. For
example, the charger function on the RS2000 may be enabled, but it will
not charge unless qualified AC power is present.
These functions can also be controlled from the System Control Panel.