11
© 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01
Connecting the Shunt Board
• Remove the fuse from the in-line fuse holder by rotating the fuse holder
cap counterclockwise.
• Connect the ring terminal from the fuse holder to the battery’s positive
terminal.
• Connect the shunt communications cable into the RJ11 jack on the shunt
board. This cable can be extended up to 100 feet (30 meters).
• Replace the fuse in the fuse holder. Replace the fuse holder cap by
pushing and rotating it clockwise.
INVERTER
-
SHUNT
DC FUSE
DISCONNECT
SHUNT IN-LINE FUSE
SHUNT WIRE
3507-00B-F01
J2
J1
INVERTER
RC4/RC8
REMOTE
JACK
GROUND WIRE
(IF RUN IS OVER
100 FEET)
SHUNT JACK
REMOTE JACK
INVERTER ON/OFF
REMOTE CABLE
TC10, TC25, TC50, TC100
(NOT SUPPLIED)
TRACE
METER
(Back View)
BATTERY
+ -
+
Figure 2-10
Circuit Diagram
Figure 2-9
In-line Fuse
In-line Fuse
To battery’s
positive
terminal
To J1
connector on
back of
meter
2.0 INSTALLATION