Xantrex Technology XPD 18-30 Power Supply User Manual


 
Section 1. Features and Specifications
Rear Panel Connectors
Release A 15
Rear Panel
J210
Connector
The J210 Analog Interface connector is a 15-pin female DSUB connector located on
the rear panel. See Figure 1.6. Use the J210 programming, monitoring, and
shutdown 15 pin DSUB connector for remote programming and monitoring
functions. See Figure 1.2 for the location of the J210 connector at the rear panel. We
recommend that you mate the J210 connector with a 15-pin male connector, such as
a Tyco 747908-2 or equivalent.
The J210 connector provides access to the following functions:
Remote programming of both output voltage and current
Calibrated readback signals for remote monitoring of output voltage and output
current
Isolated remote shutdown function using a 5-15 V signal
See Figure 1.6 for a graphic presentation of the J210 connector and its pinouts.
Figure 1.6 Analog Interface Programming and Monitoring J210 Connector
See Table 1.2 for a list of the J210 connector pin numbers, their references, and
corresponding functions.
9
1
8
15